- Product Description
CKX-20 Cement Carbon Dioxide Analyzer
CKX-20 Cement Carbon Dioxide Analyzer is a product developed according to the national standard GB/T12960-2019 <Quantitative Determination of Cement Components>. It is an indispensable device for determining the content of limestone components in cement. This method refers to the determination of carbon dioxide in the European standard EM196-2:2005 "Cement Test Methods-Cement Chemical Analysis" (English version), and the gravimetric method is used for the determination of carbon dioxide content. The CKX-20 Cement Carbon Dioxide Analyzer adopts a color touch screen, which has good human-computer interaction, simple operation, and high accuracy and accuracy of the measurement results.
Main technical parameters:
1. Carbon dioxide measurement range: ≤44%
2. Gas flow: 0~250ml/min, adjustable
3. Heating power: 500W, adjustable
4. Timing range: 0~100 minutes, adjustable
5. Ambient temperature: 10~40℃
6. Input voltage: AC/220V
7. Display mode: color touch screen
SCO-2 carbon detector
According to the GB / T12960-2007 standard requirements for the determination of the amount of limestone in cement, our company developed a SCO-2 carbon detector. The instrument is easy to use, the temperature and time can be adjusted by itself, and has an alarm function, accurate timing, reliable temperature and voltage adjustment, and low measurement cost. This product is developed according to the principle of the determination method of carbon dioxide in cement listed in the GB / T2960-2007 standard, and fully complies with the quasi-requirements of GB / T12960-2007. It is an ideal instrument for measuring the carbon dioxide content and the amount of limestone in cement.Technical Parameters1.Power supply voltage: 220V ± 10%, instrument power consumption: 150W2. Timing range: 0-99 minutes Digital display Buzzer alarm Countdown automatically cut off the heating3. Timing accuracy: <100us4. Method accuracy: average standard deviation 0.045.Measurement error: It conforms to the GB / T12960-2007 standard and is lower than the specified standard deviation:When the limestone composition is ≤10%, the error is <± 0.3%When the composition of limestone is ≥10%, the error is <± 0.6%6. Measurement time: <20 minutes7. Working environment: temperature 0 ℃ -40 ℃ relative humidity <80%8. Temperature adjustment voltage: 80V-100V digital display9. Scope of application: suitable for the determination of limestone components in general Portland cement10.Net weight: 12kg
Hot Products
Contact us
Please feel free to give your inquiry in the form below We will reply you in 24 hours